详细信息
Decoupling transient effects of factors affected by air recirculation devices on contaminant distribution in ventilated spaces ( SCI-EXPANDED收录 EI收录)
文献类型:期刊文献
英文题名:Decoupling transient effects of factors affected by air recirculation devices on contaminant distribution in ventilated spaces
作者:Shao, Xiaoliang[1];Hao, Yunfeng[1];Liu, Yu[1];Li, Xianting[2];Ma, Xiaojun[3]
第一作者:Shao, Xiaoliang
通讯作者:Li, XT[1]
机构:[1]Univ Sci & Technol Beijing, Sch Civil & Resource Engn, Beijing 100083, Peoples R China;[2]Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China;[3]Beijing Union Univ, Coll Biochem Engn, Beijing 100023, Peoples R China
第一机构:Univ Sci & Technol Beijing, Sch Civil & Resource Engn, Beijing 100083, Peoples R China
通讯机构:[1]corresponding author), Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China.
年份:2021
卷号:206
外文期刊名:BUILDING AND ENVIRONMENT
收录:;EI(收录号:20213710898440);Scopus(收录号:2-s2.0-85114838466);WOS:【SCI-EXPANDED(收录号:WOS:000700077500003)】;
基金:This study is supported by the National Natural Science Foundation of China (Grant No. 51878043), Beijing Natural Science Foundation (Grant No. 8212012) , the National Key Research and Development Program of China (Grant No. 2018YFC0705201), and Fundamental Research Funds for the Central Universities (Grant No. FRF-TP-20-001A3).
语种:英文
外文关键词:Air distribution; Air recirculation; Transient contaminant distribution; Non-uniform environment; Accessibility
摘要:The use of indoor air recirculation devices, such as air cleaners and air curtains, results in an airflow interaction between air supply jets and recirculated airflows. It is essential to quantify the independent effects of supply air, contaminant source, and initial condition in a ventilated room with air recirculation. In this paper, the transport process of a contaminant with air recirculation is mathematically derived based on a fixed flow field. A linear expression is established to describe the transient contributions of different influencing factors. The indices of revised transient accessibility of supply air (RTASA), contaminant source (RTACS), and initial condition (RTAIC), are defined to quantify the effect of each factor by incorporating the effect of air recirculation. The prediction accuracy is verified through a comparison with simulation results. The proposed indices are applied to evaluate a ventilated room with an air cleaner and recirculated air curtain. The results indicate that the recirculated airflows from both the air cleaner and air curtain increase the RTASA of each air supply inlet to distant areas. The purification effect (30%) occurs only after a certain period for RTASA and RTACS, while it operates from the initial stage for RTAIC owing to the initial high contamination. The RTACS in the protected zone is reduced significantly owing to the air curtain, with a decrease from 1.33 to 0.77 at 600 s at a height of 1.2 m in the curtain jet. The proposed method can be used to evaluate indoor environments with various air recirculation devices.
参考文献:
正在载入数据...