详细信息
文献类型:期刊文献
中文题名:Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
作者:Jingxiao Han[1];Chuanzhao Zhang[2];LuWang[3];ZengjunChang[1];Qing Zhao[1];Ying Shi[4];JiaruiWu[5];Xiangfei Kong[3]
第一作者:Jingxiao Han
机构:[1]Technical Management Department,Beijing District Heating Group Co.,Ltd.,Beijing,100028,China;[2]College of Biochemical Engineering,Beijing Union University,Beijing,100032,China;[3]School of Energy and Environmental Engineering,Hebei University of Technology,Tianjin,300401,China;[4]Technology Research and Development Department,Beijing Heating Project Design Co.,Ltd.,Beijing,100071,China;[5]Digital Intelligence Technology Center,China Railway Group Mechanical and Electrical Installation Co.,Ltd.,Beijing,100049,China
第一机构:Technical Management Department,Beijing District Heating Group Co.,Ltd.,Beijing,100028,China
年份:2023
卷号:120
期号:9
起止页码:1991-2011
中文期刊名:能源工程(英文)
外文期刊名:Energy Engineering
收录:Scopus
基金:This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001);Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
语种:英文
中文关键词:Electric heat storage;solar energy;air source heat pump;multi-objective optimization method;LOCH
摘要:For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.