毛细管电泳电致化学发光法测定家犬体内甲氧氯普胺的血药浓度  ( SCI-EXPANDED收录)  

Determination of Metoclopramide in Dog Plasma by Capillary Electrophoresis with Electrochemiluminescence

文献类型:期刊文献

中文题名:毛细管电泳电致化学发光法测定家犬体内甲氧氯普胺的血药浓度

英文题名:Determination of Metoclopramide in Dog Plasma by Capillary Electrophoresis with Electrochemiluminescence

作者:周考文[1];顾雪梅[2];崔晓超[1];陈晓翠[1]

第一作者:周考文

通讯作者:Zhou, KW[1]

机构:[1]北京联合大学生物化学工程学院;[2]中国人民解放军北京军区总医院

第一机构:北京联合大学生物化学工程学院

通讯机构:[1]corresponding author), Beijing Union Univ, Biochem Engn Coll, Beijing 100023, Peoples R China.|[1141726]北京联合大学生物化学工程学院;[11417]北京联合大学;

年份:2011

卷号:69

期号:2

起止页码:221-225

中文期刊名:化学学报

外文期刊名:Acta Chimica Sinica

收录:CSTPCD;;Scopus(收录号:2-s2.0-84867053330);WOS:【SCI-EXPANDED(收录号:WOS:000287907800018)】;北大核心:【北大核心2008】;CSCD:【CSCD2011_2012】;

基金:北京市教委科技发展计划(No.KM200711417005);北京市骨干教师人才强教计划资助项目

语种:中文

中文关键词:毛细管电泳;电化学发光;甲氧氯普胺;血药浓度

外文关键词:capillary electrophoresis; electrochemiluminescence; metoclopramide; plasma drug concentra-tion

摘要:基于甲氧氯普胺对钌联吡啶电化学发光信号的增敏作用,建立了检测甲氧氯普胺的毛细管电泳电致化学发光新方法.最佳实验条件为:检测电位1.18 V,钌联吡啶浓度5 mmol/L,检测池磷酸缓冲溶液40 mmol/L(pH 7.2),分离磷酸缓冲溶液20 mmol/L(pH 6.1),进样电压12 kV,进样时间10 s,分离电压14 kV.方法的检测限(3σ)为5.0×10-3 mg/L,线性范围为0.03~9.52 mg/L,相关系数为0.9990,回收率为98.0%~101.7%.对家犬体内甲氧氯普胺血药浓度的监测发现,给药1.5 h血药浓度达到最大值,血药浓度的半衰期约为4 h.本方法具有简便、快速、灵敏、进样量少等特点,可用于甲氧氯普胺血药浓度监控和药物动力学研究.
Based on the phenomenon that metoclopramide(MCL) could consumingly enhance the electro-chemiluminescence(ECL) intensity of tris(2,2'-bipyridyl)ruthenium,a novel and sensitive method was proposed for determination of metoclopramide using capillary electrophoresis(CE) coupled with electrochemiluminescence(ECL) detection.The influence of several experiment parameters was ex-plored.The optimum experimental conditions were detection potential 1.18 V(vs.Ag/AgCl),40 mmol/L of phosphate buffer(pH 7.2) containing 5 mmol/L in CEL detection cell,running buffer of 20 mmol/L(pH 6.1),sample injection of 10 s at 12 kV,and separation voltage of 14 kV.The detection limit(3σ) of this method was 5.0×10-3 mg/L.The linear range of ECL intensity versus concentration of meto-clopramide was 0.03~9.52 mg/L,and the correlation coefficient was 0.9990.The recovery of testing 5 standard samples by this method was 98.0%~101.7%.Maximum of MCL concentration in Dog Plasma ap-peared at 1.5 h of drugging,and half life of the concentration was about 4 h.This method had the merits of simpleness,speediness,sensitivity,little sample injection,and could successfully avoid the influencing of interference.This method was successfully utilized to the assay of metoclopramide in dog plasma.